BZZYF - 810 STEEL PUTTY PLUS PART A
- MSDS: BZZYF
- Manufacturer: A W CHESTERTON CO
- Product Name: 810 STEEL PUTTY PLUS PART A
- National Stock Number: 8030-00N016826
Product Identification
Product ID:810 STEEL PUTTY PLUS PART A
MSDS Date:03/01/1991
FSC:8030
NIIN:00N016826
MSDS Number: BZZYF
Responsible Party
STONEHAM, MA 02180-2999
US
Emergency Phone: 617-438-7000
Info Phone: 617-438-7013
Cage: 71431
Contractor
Telephone: 781-438-7000/800-535-5053
Cage: 71431
Ingredients
BISPHENOL A-EPICHLOROHYDRIN COPOLYMER; (BISPHENOL A
CAS: 25068-38-6
RTECS: SL6475000
Fraction By Weight: 10-20%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MODERATE EYE AND SKIN IRRITANT.
MAY CAUSE SKIN SENSITIZATION AS EVIDENCED BY RASHES OR HIVES.
CHRONIC: ALTHOUGH THE SIGNIFICANCE IS UNKNOWN, BISPHENOL A
DIGLYCIDYL ETHER RESIN HAS BEEN SHOWN TO BE MUTAGENIC IN SOME
MICROBIAL TESTS BUT HAS FAILED TO SHOW MUTAGENICITY IN OTHERS.
CHROMOSOMAL (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: ABERRATIONS WERE OBSERVED IN CULTURED
RAT LIVER CELLS. BASED ON RECENT 2-YEAR MICE SKIN PAINTING STUDIES
AND OTHER AVAILABLE INFORMATION, IARC CONCLUDED THEY DID NOT HAVE
ENOUGH INFORMATION TO CLASSIFY BISPHENOL A DIGLYCIDYL ETHER RESIN.
Medical Cond Aggravated by Exposure:PERSONNEL WITH PRE-EXISTING
ALLERGIES MAY BE AGGRAVATED BY EXPOSURE.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
OXYGEN/ARTIFICIAL RESPIRATION) . SKIN: REMOVE CONTAMINATED
CLOTHING. WASH SKIN WITH SOAP AND WATER. CONSULT MD IF IRRITATION
PERSISTS. EYES: F LUSH EYES FOR AT LEAST 15 MINUTES WITH LARGE
QUANTITIES OF WATER. CONSULT MD IF IRRITATION PERSISTS. INGEST: DO
NOT INDUCE VOMITING. CONTACT MD IMMEDIATELY.
Fire Fighting
Flash Point Method:CC
Flash Point:480F,249C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM OR WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . COOL EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION CAN FORM ALDEHYDES,
ACIDS OR OTHER TOXIC FUMES.
Accidental Release
Spill Release Procedures:AVOID SKIN CONTACT. SCOOP UP AND TRANSFER TO A
SUITABLE CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN COOL, DRY AREA.
Other Precautions:REMOVE CONTAMINATED CLOTHING IMMEDIATELY. WASH
CLOTHING BEFORE REUSE. CONTAMINATED LEATHER INCLUDING SHOES CANNOT
BE DECONTAMINATED SO THEY SHOULD BE DISCARDED.
Exposure Controls
Respiratory Protection:NOT NEEDED. USE NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NO SPECIAL REQUIREMENTS.
Protective Gloves:CHEM RESISTANT GLOVES (EG NEOPRENE).
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
IMPERVIOUS CLOTHING AS NECESSARY TO PREVENT SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Vapor Density:>1
Spec Gravity:2.2
Evaporation Rate & Reference:<1 (ETHER =1)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:<1
Stability
Stability Indicator/Materials to Avoid:YES
STRONG MINERAL ACIDS, STRONG OXIDIZERS LIKE LIQUID CHLORINE AND
CONCENTRATED OXYGEN.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:CARBON MONOXIDE, ALDEHYDES, ACIDS AND
OTHER TOXIC FUMES.
Disposal
Waste Disposal Methods:LANDFILL SEALED CONTAINERS IN AN APPROVED AREA.
CHECK LOCAL, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.